The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.
CARACTERíSTICAS DEL PRODUCTO
Meter with or without GPS
Built in GPS Receiver
- 12 channel GPS receiver and antenna
- Tracks location using satellites to within 30 feet
- Latitude and longitude recorded with readings
- Location naming for GPS coordinates
- Distance from current location to stored location
- Hi929829 software supplied integrates data collected with Google™ maps
- Measurement readings including GPS coordinates
- Date and time
- Named locations and remarks
- Sample number
Google™ maps is a registered trademark of Google™, Inc. HANNA Instruments® has no affiliation with Google™.
Two probes to choose from (Basic or Logging)
The HI7609829 (basic) and HI7629829 (logging) are multiparameter probes for use with the HI9829 portable meter. It is an option to choose which probe will be supplied with the HI9829. By default the HI9829 and corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.
HI7609829 Basic Probe
- Digital probe that is less than 2 inches in diameter
- 3 color-coded sensor inputs
- IP68 rating for continuous immersion in water
- Multistrand –mulitconductor cable rated for 150 lbs (intermittent use)
- Available with 4, 10, or 20 meter cable
- Weighted shield protects all sensors
HI7629829 Autonomously Logging Probe
- Same as basic probe but with logging capability
- Logs data independent of HI9829 meter
- Operates on 4 “AA” batteries for up to 70 days*
- Stores up to 140,000 single parameter readings or 35,000 for all parameters
- Logs data from 1 second to 3 hours
- Choose to be supplied with EC or EC/Turbidity sensor
- Supplied with USB cable for direct connection to Window’s compatible PC
*All channels logging at 10 minute intervals with no averaging
Waterproof Protection – The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.
Backlit Dot Matrix LCD Display – The HI9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.
Dedicated Help Key – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
Auto-sensor Recognition – The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.
Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.
Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.
GLP Data – HI9829 includes a GLP feature thatallows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
Data Logging – The HI9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours.
Graphing Capability – Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.
PC Connectivity – Logged data can be transferred to a Windows compatible PC with the included HI7698291 USB adapter and HI929829 software.
Long Battery Life – The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C “ NiMH rechargeable batteries that provide up to 140 hours of battery life*
Rugged thermoformed carrying case – The HI9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.
* Without GPS or turbidity measurements
On-screen Features
GPS OptionThe meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data.
Quick CalibrationThe quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps.
Graphing CapabilityTrend graphing with sample date and time may be viewed on the display or transferred to PC.
Fast Tracker™—Tag Identification System
HANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.
iButton. Tags are Easy to Install
Install the optional TAGs near your sampling points for quick and easy iButton. readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.
Peso |
6 , 6 kg |
---|
Valorado en 0 de 5
0 comentarios
Valorado en 5 de 5
0
Valorado en 4 de 5
0
Valorado en 3 de 5
0
Valorado en 2 de 5
0
Valorado en 1 de 5
0
Sé el primero en valorar “HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option-No-Basic probe – with turbidity-10m (32.8′)” Cancelar respuesta
Especificaciones
Intervalo de pH | 0.00 a 14.00 pH |
Resolución de pH | 0.01 pH |
Exactitud de pH | ± 0.02 pH |
Calibración del pH | Automática en uno, dos o tres puntos con reconocimiento automático de cinco soluciones estándar (pH 4.01, 6.86, 7.01, 9.18, 10.01) o un valor personalizado |
Intervalo de mV | ± 600.0 mV |
Resolución de mV | 0.1 mV |
Exactitud de mV | ± 0.5 mV |
Intervalo de ORP | ± 2.000 mV |
Resolución de ORP | 0.1 mV |
Exactitud de ORP | ± 1.0 mV |
Calibración de ORP | Automático en un punto personalizado (mV relativo) |
Intervalo de CE | 0 a 200 mS / cm (CE absoluta hasta 400 mS/cm) |
Resolución de CE | Manual: 1 µS / cm; 0.001 mS / cm; 0.1 mS / cm; 0.1 mS / cm; 1 mS / cm, Automático: 1 µS / cm de 0 a 9999 µS / cm; 0,01 mS / cm de 10.00 a 99.99 mS / cm; 0.1 mS / cm de 100.0 a 400.0 mS / cm, Automático (mS / cm): 0. 01 mS / cm de 0.000 a 9.999 mS / cm; 0.01 mS / cm de 10,00 a 99.99 mS / cm; 0.1 mS / cm de 100.0 a 400.0 mS / cm |
Exactitud de CE | ± 1% de la lectura o ± 1 µS/cm lo que sea mayor |
Calibración de CE | Con seis soluciones estándar (84 µS / cm, 1,413 µS / cm, 5.00 mS / cm, 12.88 mS / cm, 80.0 mS / cm, 111,8 mS/cm) o punto personalizado |
Intervalo de TDS | 0 a 400,000 ppm (mg/L); (El valor máximo depende del factor TDS) |
Resolución de TDS | Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automático: 1 ppm (mg/L) de 0 a 9,999 ppm (mg/L); 0.01 ppt (g/L) de 10.00 a 99.99 ppt (g/L); 0.1 ppt (g/L) de 100.0 a 400.0 ppt (g/L), ppt (g/L) automático: 0.001 ppt (g/L) de 0.000 a 9.999 ppt (g/L); 0.01 ppt (g/L de 10.00 a 99.99 ppt (g/L); 0.1 ppt (g/L) de 100.0 a 400.0 ppt (g/L) |
Exactitud de TDS | ± 1% de la lectura o ± 1 ppm (mg / L), lo que sea mayor |
Calibración de TDS | Basado en la calibración de conductividad o salinidad |
Intervalo de resistividad | 0 a 999,999 O • cm; 0 a 1000.0 kO • cm; 0 a 1.0000 MO • cm |
Calibración de resistividad | Basado en la calibración de la conductividad |
Intervalo de salinidad | 0.00 a 70.00 PSU |
Resolución de salinidad | 0.01 PSU |
Exactitud de salinidad | ± 2% de la lectura o ± 0,01 PSU, el que sea mayor |
Calibración de salinidad | Basado en la calibración de la conductividad |
Intervalo de medición en agua de mar | 0,0 a 50,0 st, s0, s15 |
Resolución de agua de mar s | 0,1 st, s0, s15 |
Exactitud del agua de mar s | ± 1 st, s0, s15 |
Calibración s del agua de mar | Basado en la calibración de conductividad o salinidad |
Intervalo de nitrógeno amónico | 0.02 a 200.0 ppm (como NH4 - N) |
Resolución de nitrógeno amónico | 0,01 ppm a 1 ppm 0.1 ppm a 200.0 ppm |
Exactitud de nitrógeno amónico | ± 5% de lectura o 2 ppm |
Calibración de nitrógeno amónico | 1 o 2 puntos, 10 ppm y 100 ppm |
Intervalo de cloruro | 0.6 a 200.0 ppm de Cl (como Cl-) |
Resolución de cloruro | 0.01 ppm a 1 ppm 0.1 ppm a 200.0 ppm |
Exactitud de cloruro | ± 5% de la lectura o 2 ppm |
Calibración de cloruro | 1 o 2 puntos, 10 ppm y 100 ppm |
Intervalo del nitrógeno de nitrato | 0.62 a 200.0 ppm de Ni (como NO _ {3} - N) |
Resolución nitrógeno de nitrato | 0.01 ppm a 1 ppm 0.1 ppm a 200 ppm |
Exactitud del nitrógeno de nitrato | ± 5% de la lectura o 2 ppm |
Calibración nitrógeno de nitrato | 1 o 2 puntos, 10 ppm y 100 ppm |
Intervalo de turbidez | 0,0 a 99.9 FNU; 100 a 1000 FNU |
Resolución de turbidez | 0.1 FNU de 0.0 a 99.9 FNU 1 FNU de 100 a 1,000 FNU |
Exactitud de turbidez | ± 0.3 FNU o ± 2% de la lectura, lo que sea mayor |
Calibración de turbidez | Automático 1, 2 o 3 puntos a 0, 20 y 200 FNU, o personalizado |
Intervalo de OD | 0.0 a 500.0%; 0,00 a 50.00 ppm (mg / l) |
Resolución de OD | 0.1%; 0.01 ppm (mg / l) |
Exactitud de OD | 0.0 a 300.0% de saturación: ± 1.5% de la lectura o ± 1.0% de saturación, lo que sea mayor, 0.00 a 30.00 ppm (mg / L): ± 1.5% de la lectura o ± 0.10 ppm (mg / L) ppm (mg/L) a 50.00 ppm (mg/L): ± 3% de la lectura, 300.0 a 500.0 % saturación: ± 3% de la lectura |
Calibración de OD | Automático uno o dos puntos a 0 y 100% o un punto personalizado |
Intervalo de presión atmosférica | 450 a 850 mm Hg; 17.72 a 33.46 en Hg; 600.0 a 1133.2 mbar; 8.702 a 16.436 psi; 0.5921 a 1.1184 atm; 60.00 a 113.32 kPa |
Resolución de presión atmosférica | 0.1 mm Hg; 0.01 en Hg; 0,1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Exactitud de presión atmosférica | ± 3 mm Hg a ± 15 ° C de la temperatura durante la calibración |
Calibración de presión atmosférica | Automático en un punto personalizado |
Intervalo de temperatura | -5.00 a 55.00 ° C, 23.00 a 131.00 ° F, 268.15 a 328,15 K |
Resolución de temperatura | 0.01 K, 0.01 °C, 0.01 °F |
Exactitud de temperatura | ±0.15ºC; ±0.27 °F; ± 0.15 K |
Calibración de temperatura | Automático en un punto personalizado |
Compensación de temperatura | Automático de -5 a 55 °C (23 a 131 ° F) |
Memoria de registro | 44.000 registros (registro continuo o registro a petición de todos los parámetros) |
Intervalo de registro | Un segundo a tres horas |
Conectividad del PC | USB (con software HI 929829) |
Tipo de batería / duración | 1.2V (4) NiMH, baterías recargables, tamaño C; Hasta 140 horas dependiendo de la configuración |
Clasificación de la protección | IP67 |
Condiciones ambientales | 0 a 50 ° C (32 a 122 ° F); HR máx. 100% |
Dimensiones | 221 x 115 x 55 mm (8.7 x 4.5 x 2.2 ") |
Peso | 750 g (26.5 onzas) |
GPS | Receptor de 12 canales con 10 m (30 pies) de precisión |
Información para ordenar | El HI9829 y el HI98290 (modelo GPS) se suministran con un maletín de transporte HI710140, adaptador HI7612VDC, kit de mantenimiento de la sonda HI7698292, software de aplicación HI929829 para PC, cable USB HI7698291 (PC al medidor), cable de alimentación HI710045, adaptador de corriente para auto HI710046, sensor de pH/ORP HI7609829-1, sensor galvánico de OD HI7609829-2, sensor de CE HI7609829-3, vaso corto de calibración HI7698290, HI7698295 protector corto con punta de acero inoxidable, baterías de NiMH recargables tipo "C"(4), adaptador de corriente de 12VCD y manual de instrucciones.
Las sondas con la opción de turbidez incluirán el sensor de CE/turbidez HI7609829-4, vaso de calibración largo HI7698293 y protector largo con punta de acero inoxidable HI7698296, en lugar del sensor de CE, del vaso de calibración corto y del protector corto. Las sondas seleccionadas con opción de turbidez incluirán también soluciones de calibración de turbidez (230 ml) HI9829-16 de 0 FNU, HI769829-17 de 20 FNU, y HI9829-18 de 200 FNU. |