SKU: HI 97747

Copper Low-Range Portable Photometer-meter only

$467.690

+ IVA

Disponible Pronto

Disponible para entrega hasta en 90 días.

Disponible Pronto

HI97747 is an advanced portable photometer for the measurement of copper in water. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements. 

  • No warm up time before taking a measurement
  • Tutorial mode for step-by-step instructions
  • CAL Check to verify meter performance

CARACTERíSTICAS DEL PRODUCTO

Due to its malleability, thermal and electrical conductivity, and corrosion resistance, copper is used in a variety of industrial and technological applications. Copper may also be present in natural water and effluents due to widespread use to control biological growths in reservoirs and distribution pipes.The HI97747 uses the bicinchoninate method to measure copper in water with concentrations of up to 1.500 mg/L (ppm). When the reagent is added to samples containing copper, the sample will turn a purple hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law which states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For lower levels of copper, a narrow band interference filter at 575 nm allows only green-yellow light to be emitted and passed through the sample cuvette. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.This innovative optical system offers superior performance in accuracy, repeatability, and required time to perform a measurement. This compact, waterproof meter has a tutorial mode that walks the user graphically, step by step, to perform a measurement. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use.

photometer optical system

  • LED that generates very little heat.
  • 8 nm narrowband interference filter that is accurate to +/- 1 nm.
  • Reference detector that modulates the voltage to LED for consistent light output.
  • A concave focusing lens that reduces errors from imperfections in the cuvette.

 

On-Screen Features

CAL CheckAdvanced features including CAL-Check to verify performance and if necessary, recalibrate.

method option

Setup OptionsBacklit dot matrix LCD that offers an exceptionally intuitive user interface that is easy to read and understand.

Tutorial ModeTutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.

Reaction TimerBuilt-in reaction timer that ensures consistency amongst multiple users.

 

HI97747 FEATURES/BENEFITS:

Stable Light Source:

  • The internal reference system of the HI97747 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.

High Efficiency Light Source:

  • LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.

High Quality Filters:

  • Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

Greater Light Yield:

  • A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.

CAL Check Functionality:

  • Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.

 

Large Cuvette Size:

  • The sample cell of the HI97747 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Intuitive Dot Matrix Display:

  • The HI97747 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

Auto-off Protection:

  • The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.
Peso

0 , 5 kg

0 comentarios
0
0
0
0
0

Valoraciones

Borrar filtros

No hay valoraciones aún.

Sé el primero en valorar “Copper Low-Range Portable Photometer-meter only”

Tu dirección de correo electrónico no será publicada. Los campos requeridos están marcados *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5

Especificaciones

Intervalo de pH 0.00 a 14.00 pH
Resolución de pH 0.01 pH
Exactitud de pH ± 0.02 pH
Calibración del pH Automática en uno, dos o tres puntos con reconocimiento automático de cinco soluciones estándar (pH 4.01, 6.86, 7.01, 9.18, 10.01) o un valor personalizado
Intervalo de mV ± 600.0 mV
Resolución de mV 0.1 mV
Exactitud de mV ± 0.5 mV
Intervalo de ORP ± 2.000 mV
Resolución de ORP 0.1 mV
Exactitud de ORP ± 1.0 mV
Calibración de ORP Automático en un punto personalizado (mV relativo)
Intervalo de CE 0 a 200 mS / cm (CE absoluta hasta 400 mS/cm)
Resolución de CE Manual: 1 μS / cm; 0.001 mS / cm; 0.1 mS / cm; 0.1 mS / cm; 1 mS / cm, Automático: 1 μS / cm de 0 a 9999 μS / cm; 0,01 mS / cm de 10.00 a 99.99 mS / cm; 0.1 mS / cm de 100.0 a 400.0 mS / cm, Automático (mS / cm): 0. 01 mS / cm de 0.000 a 9.999 mS / cm; 0.01 mS / cm de 10,00 a 99.99 mS / cm; 0.1 mS / cm de 100.0 a 400.0 mS / cm
Exactitud de CE ± 1% de la lectura o ± 1 μS/cm lo que sea mayor
Calibración de CE Con seis soluciones estándar (84 μS / cm, 1,413 μS / cm, 5.00 mS / cm, 12.88 mS / cm, 80.0 mS / cm, 111,8 mS/cm) o punto personalizado
Intervalo de TDS 0 a 400,000 ppm (mg/L); (El valor máximo depende del factor TDS)
Resolución de TDS Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automático: 1 ppm (mg/L) de 0 a 9,999 ppm (mg/L); 0.01 ppt (g/L) de 10.00 a 99.99 ppt (g/L); 0.1 ppt (g/L) de 100.0 a 400.0 ppt (g/L), ppt (g/L) automático: 0.001 ppt (g/L) de 0.000 a 9.999 ppt (g/L); 0.01 ppt (g/L de 10.00 a 99.99 ppt (g/L); 0.1 ppt (g/L) de 100.0 a 400.0 ppt (g/L)
Exactitud de TDS ± 1% de la lectura o ± 1 ppm (mg / L), lo que sea mayor
Calibración de TDS Basado en la calibración de conductividad o salinidad
Intervalo de resistividad 0 a 999,999 Ω • cm; 0 a 1000.0 kΩ • cm; 0 a 1.0000 MΩ • cm
Calibración de resistividad Basado en la calibración de la conductividad
Intervalo de salinidad 0.00 a 70.00 PSU
Resolución de salinidad 0.01 PSU
Exactitud de salinidad ± 2% de la lectura o ± 0,01 PSU, el que sea mayor
Calibración de salinidad Basado en la calibración de la conductividad
Intervalo de medición en agua de mar 0,0 a 50,0 σt, σ₀, σ₁₅
Resolución de agua de mar σ 0,1 σt, σ₀, σ₁₅
Exactitud del agua de mar σ ± 1 σt, σ₀, σ₁₅
Calibración σ del agua de mar Basado en la calibración de conductividad o salinidad
Intervalo de nitrógeno amónico 0.02 a 200.0 ppm (como NH4+ - N)
Resolución de nitrógeno amónico 0,01 ppm a 1 ppm 0.1 ppm a 200.0 ppm
Exactitud de nitrógeno amónico ± 5% de lectura o 2 ppm
Calibración de nitrógeno amónico 1 o 2 puntos, 10 ppm y 100 ppm
Intervalo de cloruro 0.6 a 200.0 ppm de Cl (como Cl-)
Resolución de cloruro 0.01 ppm a 1 ppm 0.1 ppm a 200.0 ppm
Exactitud de cloruro ± 5% de la lectura o 2 ppm
Calibración de cloruro 1 o 2 puntos, 10 ppm y 100 ppm
Intervalo del nitrógeno de nitrato 0.62 a 200.0 ppm de Ni (como NO _ {3} - N)
Resolución nitrógeno de nitrato 0.01 ppm a 1 ppm 0.1 ppm a 200 ppm
Exactitud del nitrógeno de nitrato ± 5% de la lectura o 2 ppm
Calibración nitrógeno de nitrato 1 o 2 puntos, 10 ppm y 100 ppm
Intervalo de turbidez 0,0 a 99.9 FNU; 100 a 1000 FNU
Resolución de turbidez 0.1 FNU de 0.0 a 99.9 FNU 1 FNU de 100 a 1,000 FNU
Exactitud de turbidez ± 0.3 FNU o ± 2% de la lectura, lo que sea mayor
Calibración de turbidez Automático 1, 2 o 3 puntos a 0, 20 y 200 FNU, o personalizado
Intervalo de OD 0.0 a 500.0%; 0,00 a 50.00 ppm (mg / l)
Resolución de OD 0.1%; 0.01 ppm (mg / l)
Exactitud de OD 0.0 a 300.0% de saturación: ± 1.5% de la lectura o ± 1.0% de saturación, lo que sea mayor, 0.00 a 30.00 ppm (mg / L): ± 1.5% de la lectura o ± 0.10 ppm (mg / L) ppm (mg/L) a 50.00 ppm (mg/L): ± 3% de la lectura, 300.0 a 500.0 % saturación: ± 3% de la lectura
Calibración de OD Automático uno o dos puntos a 0 y 100% o un punto personalizado
Intervalo de presión atmosférica 450 a 850 mm Hg; 17.72 a 33.46 en Hg; 600.0 a 1133.2 mbar; 8.702 a 16.436 psi; 0.5921 a 1.1184 atm; 60.00 a 113.32 kPa
Resolución de presión atmosférica 0.1 mm Hg; 0.01 en Hg; 0,1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Exactitud de presión atmosférica ± 3 mm Hg a ± 15 ° C de la temperatura durante la calibración
Calibración de presión atmosférica Automático en un punto personalizado
Intervalo de temperatura -5.00 a 55.00 ° C, 23.00 a 131.00 ° F, 268.15 a 328,15 K
Resolución de temperatura 0.01 K, 0.01 °C, 0.01 °F
Exactitud de temperatura ±0.15ºC; ±0.27 °F; ± 0.15 K
Calibración de temperatura Automático en un punto personalizado
Compensación de temperatura Automático de -5 a 55 °C (23 a 131 ° F)
Memoria de registro 44.000 registros (registro continuo o registro a petición de todos los parámetros)
Intervalo de registro Un segundo a tres horas
Conectividad del PC USB (con software HI 929829)
Tipo de batería / duración 1.2V (4) NiMH, baterías recargables, tamaño C; Hasta 140 horas dependiendo de la configuración
Clasificación de la protección IP67
Condiciones ambientales 0 a 50 ° C (32 a 122 ° F); HR máx. 100%
Dimensiones 221 x 115 x 55 mm (8.7 x 4.5 x 2.2 ")
Peso 750 g (26.5 onzas)
GPS Receptor de 12 canales con 10 m (30 pies) de precisión
Información para ordenar El HI9829 y el HI98290 (modelo GPS) se suministran con un maletín de transporte HI710140, adaptador HI7612VDC, kit de mantenimiento de la sonda HI7698292, software de aplicación HI929829 para PC, cable USB HI7698291 (PC al medidor), cable de alimentación HI710045, adaptador de corriente para auto HI710046, sensor de pH/ORP HI7609829-1, sensor galvánico de OD HI7609829-2, sensor de CE HI7609829-3, vaso corto de calibración HI7698290, HI7698295 protector corto con punta de acero inoxidable, baterías de NiMH recargables tipo "C"(4), adaptador de corriente de 12VCD y manual de instrucciones.

Las sondas con la opción de turbidez incluirán el sensor de CE/turbidez HI7609829-4, vaso de calibración largo HI7698293 y protector largo con punta de acero inoxidable HI7698296, en lugar del sensor de CE, del vaso de calibración corto y del protector corto. Las sondas seleccionadas con opción de turbidez incluirán también soluciones de calibración de turbidez (230 ml) HI9829-16 de 0 FNU, HI769829-17 de 20 FNU, y HI9829-18 de 200 FNU.

 

Descargar Manuales 

SERVICIO TÉCNICO HANNA

En HANNA® INSTRUMENTS contamos con un centro de Servicio Técnico autorizado donde usted podrá contar con la asesoría de Ingenieros capacitados que le brindarán los servicios de mantenimiento, reparación y validación de nuestros equipos.