SKU: HI 97716C

Bromine Portable Photometer-kit

$721.350

+ IVA

Disponible Pronto

Disponible para entrega hasta en 90 días.

Disponible Pronto

HI97716 is an advanced portable photometer for the measurement of bromine in water. This meter offers a superior optical system that utilizes a reference detector and narrow band interference filters for extremely fast and repeatable measurements. 

  • No warm up time before taking a measurement
  • Tutorial mode for step-by-step instructions
  • CAL Check to verify meter performance

CARACTERíSTICAS DEL PRODUCTO

In some areas around the world, bromine is replacing other more common sanitizers, such as chlorine. Due to its stability at higher temperatures and higher pH levels, bromine is most often used in sanitization of pools and spas, and cooling towers.The HI97716 uses an adaptation of the DPD method per Standard Methods for the Examination of Water and Wastewater, 23rd Edition, to measure bromine concentrations up to 10.00 mg/L (ppm). When the DPD reagent is added to samples containing bromine, the sample turns a pink hue; the greater the concentration, the deeper the color. The associated color change is colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For bromine determination, a narrow band interference filter at 525 nm allows only green light to be emitted and passed through the sample cuvette. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.

photometer optical system
  • LED that generates very little heat.
  • 8 nm narrowband interference filter that is accurate to +/- 1 nm.
  • Reference detector that modulates the voltage to LED for consistent light output.
  • A concave focusing lens that reduces errors from imperfections in the cuvette.

 

On-Screen Features

CAL CheckAdvanced features including CAL-Check to verify performance and if necessary, recalibrate.

Multiple Chemical FormsResults can be displayed in multiple chemical forms.

method option

Setup OptionsBacklit dot matrix LCD that offers an exceptionally intuitive user interface that is easy to read and understand.

Tutorial ModeTutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.

Reaction TimerBuilt-in reaction timer that ensures consistency amongst multiple users.

 

HI97716 FEATURES/BENEFITS:

Stable Light Source:

  • The internal reference system of the HI97716 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.

High Efficiency Light Source:

  • LED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.

High Quality Filters:

  • Improved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.

Greater Light Yield:

  • A focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.

CAL Check Functionality:

  • Hanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.

 

Large Cuvette Size:

  • The sample cell of the HI97716 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Intuitive Dot Matrix Display:

  • The HI97716 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.

Auto-off Protection:

  • The meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.
Peso

1 kg

0 comentarios
0
0
0
0
0

Valoraciones

Borrar filtros

No hay valoraciones aún.

Sé el primero en valorar “Bromine Portable Photometer-kit”

Tu dirección de correo electrónico no será publicada. Los campos requeridos están marcados *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5

Seleccione el electrodo de punta plana que se adapte mejor a sus requerimientos dentro de las siguientes características técnicas:

Código Cable Conexión Sensor interno de temperatura Tipo de vidrio Unión
 HI1006-4005  5m (16.4')  BNC  No Resistente al Fluoruro (HF)  PTFE
 HI1006-2405  5m (16.4')  BNC Pt1000 Usos generales (GP) PTFE
 HI1006-3005  5m (16.4')  BNC  No Alta temperatura (HT) PTFE
 HI1006-3007  7m (22.97')  BNC No Alta temperatura (HT) PTFE
 HI1006-3205  5m (16.4')  BNC Pt100 Alta temperatura (HT) PTFE
 HI1006-2005 5m (16.4')  BNC No Usos generales (GP) PTFE
 HI1006-1005  5m (16.4')  BNC No Baja temperatura (LT) PTFE
 HI1016-3005  5m (16.4')  BNC No Alta temperatura (HT) Cerámica
 HI1006-1007  7m (22.97')  BNC No Baja temperatura (LT) PTFE
 HI1006-2010  10m (32.8')  BNC No Usos generales (GP) PTFE
 HI1006-2015  15m (49.2')  BNC No Usos generales (GP) PTFE
 HI1006-3010  10m (32.8')  BNC No Alta temperatura (HT) PTFE
 HI1006-2210  10m (32.8')  BNC Pt100 Usos generales (GP) PTFE
 HI1006-1205  5m (16.4')  BNC Pt100 Baja temperatura (LT) PTFE
 HI1006-2205  5m (16.4')  BNC Pt100 Usos generales (GP) PTFE
 HI1006-2305  5m (16.4')  Directo/cables codificados por color Pt100 Usos generales (GP) PTFE
 HI1006-2505  5m (16.4')  Directo/cables codificados por color Pt1000 Usos generales (GP) PTFE
 HI1006-4205  5m (16.4')  BNC  Pt100 Resistente al Fluoruro (HF) PTFE
 HI1006-2215  15m (49.2')  BNC  Pt100 Usos generales (GP) PTFE
 HI1006-3715  15m (49.2')  Directo/cables codificados por color  Pt100 Alta temperatura (HT) PTFE

Descargar Manuales 

SERVICIO TÉCNICO HANNA

En HANNA® INSTRUMENTS contamos con un centro de Servicio Técnico autorizado donde usted podrá contar con la asesoría de Ingenieros capacitados que le brindarán los servicios de mantenimiento, reparación y validación de nuestros equipos.