Conductivity Mini Controller (0 – 1999 S/cm) 12VDC – BL983313-0
The BL983313 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0 to 1999 ?S/cm range. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a dosing pump or a solenoid that controls a valve.
Multicolor LED Indicator
LED changes color based on status.
Fire Retardant Casing
For additional safety the controllers outer case is made of fire resistant plastic.
Splash Resistant Cover
A clear plastic cover protects the face panel from dirt and liquids.
Productos Complementarios
Solución de Limpieza para Proteínas (500 mL) – HI7073L
Stock Disponible
Tester de pH / ORP / Temperatura – HI98121
Stock Disponible
$347.200+ IVA
DISPONIBLE
Agotado
SKU: BL 983313-0
Adjustable Dry Contact Dosing Relay
The BL983313 features a dosing relay that is activated when the reading is above a user programmable set point.
Programmable Overdose Protection
For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.
Relay Control Override
With the flick of a switch the mini controller’s relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.
Multicolor LED Indicator
Multicolor LED indicator allows an operator to quickly check the status of the controller.
- Green = Meter in measurement mode and reading is below the set point.
- Orange/Yellow = Reading is above the set point and the relay is activated.
- Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.
Fuse Protected Dosing Contacts
The relay dosing contact is rated for up to a 2A load and is fuse protected.
Labeled Termination Connections
Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.
1/2″ NPT Male Threaded Amperometric Probe for Mounting In-line*
The BL983313 mini controller uses the HI7634 conductivity probe that is available with different cable lengths.
*HI7634 is not included and must be ordered separately
Front View
Installation cut-out dimensions are provided as well as outside panel dimensions.
Side View
Adjustable location brackets allow the controller to slide easily and securely into place..
No hay archivos descargables disponibles para este producto.
| Código | BL983313 |
| Intervalo de CE | 0 a 1,999 µS/cm |
| Resolución de CE | 1 µS/cm |
| Exactitud de CE (@25°C/77°F) | ±2% de la escala completa. |
| Compensación de temperatura | Automática de 5 a 50°C (41 a 122°F) con ß =2%/ºC |
| Calibración | manual, con potenciómetro CAL |
| Relevador de dosificación | máximo 2A (protegido por fusible), 250 VCA, 30 VCD, el contacto se cierra cuando la lectura > punto de ajuste |
| Punto de ajuste | seleccionable de 0 a 1,999 µS/cm |
| Sobredosificación | ajustable, típicamente desde 5 hasta aproximadamente 30 minutos |
| Alimentación eléctrica | Modelos “-0”: 12 VCD con adaptador (incluido); modelos “-1”: 115/230 VCA; 50/60Hz |
| Dimensiones | 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’) |
| Peso | modelos “-0”: 200 g (7.1 oz.) modelos “-1”: 300 g (10.6 oz.) |
| Información para ordenar | Se suministra con accesorios de montaje, cubierta transparente y manual de instrucciones. |
| Sonda recomendada | HI7634-00 CE/TDS con sensor interno de temperatura y 2 m (6.6’) de cable (sonda no incluida). |
Conductivity Mini Controller (0 – 1999 S/cm) 12VDC – BL983313-0
The BL983313 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0 to 1999 ?S/cm range. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a dosing pump or a solenoid that controls a valve.
Multicolor LED Indicator
LED changes color based on status.
Fire Retardant Casing
For additional safety the controllers outer case is made of fire resistant plastic.
Splash Resistant Cover
A clear plastic cover protects the face panel from dirt and liquids.
$347.200+ IVA
DISPONIBLE
Agotado
SKU: BL 983313-0
Adjustable Dry Contact Dosing Relay
The BL983313 features a dosing relay that is activated when the reading is above a user programmable set point.
Programmable Overdose Protection
For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.
Relay Control Override
With the flick of a switch the mini controller’s relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.
Multicolor LED Indicator
Multicolor LED indicator allows an operator to quickly check the status of the controller.
- Green = Meter in measurement mode and reading is below the set point.
- Orange/Yellow = Reading is above the set point and the relay is activated.
- Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.
Fuse Protected Dosing Contacts
The relay dosing contact is rated for up to a 2A load and is fuse protected.
Labeled Termination Connections
Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.
1/2″ NPT Male Threaded Amperometric Probe for Mounting In-line*
The BL983313 mini controller uses the HI7634 conductivity probe that is available with different cable lengths.
*HI7634 is not included and must be ordered separately
Front View
Installation cut-out dimensions are provided as well as outside panel dimensions.
Side View
Adjustable location brackets allow the controller to slide easily and securely into place..
Valoraciones
Borrar filtrosNo hay valoraciones aún.
No hay archivos descargables disponibles para este producto.
| Código | BL983313 |
| Intervalo de CE | 0 a 1,999 µS/cm |
| Resolución de CE | 1 µS/cm |
| Exactitud de CE (@25°C/77°F) | ±2% de la escala completa. |
| Compensación de temperatura | Automática de 5 a 50°C (41 a 122°F) con ß =2%/ºC |
| Calibración | manual, con potenciómetro CAL |
| Relevador de dosificación | máximo 2A (protegido por fusible), 250 VCA, 30 VCD, el contacto se cierra cuando la lectura > punto de ajuste |
| Punto de ajuste | seleccionable de 0 a 1,999 µS/cm |
| Sobredosificación | ajustable, típicamente desde 5 hasta aproximadamente 30 minutos |
| Alimentación eléctrica | Modelos “-0”: 12 VCD con adaptador (incluido); modelos “-1”: 115/230 VCA; 50/60Hz |
| Dimensiones | 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’) |
| Peso | modelos “-0”: 200 g (7.1 oz.) modelos “-1”: 300 g (10.6 oz.) |
| Información para ordenar | Se suministra con accesorios de montaje, cubierta transparente y manual de instrucciones. |
| Sonda recomendada | HI7634-00 CE/TDS con sensor interno de temperatura y 2 m (6.6’) de cable (sonda no incluida). |
Productos Complementarios
Electrodo de Ion Selectivo (ISE) Combinado para Plata / Sulfuro – HI4115
Stock Disponible
Kit Químico Educacional de Pruebas para Ciencias Marinas Backpack Lab – HI3899BP
Stock Disponible
Solución de Limpieza de Electrodos para Sustancias Inorgánicas (500 mL) – HI7074L
Stock Disponible
TTester de pH inalámbrico HALO2 Carne
Consultar Disponibilidad










DQO 

Valoraciones
Borrar filtrosNo hay valoraciones aún.