TDS Mini Controller (0.0 to 199.9 ppm) – BL983315-2 | 115/230 VAC, Output: 4-20 mA
The BL983315 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) of a process stream that is within the 0.0 to 199.9 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983315 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.*The BL983315 uses a 0.5 conversion factor in which 1.0 ?S/cm = 0.5 ppm.?
Multicolor LED Indicator
LED changes color based on status.
Fire Retardant Casing
For additional safety the controllers outer case is made of fire resistant plastic.Splash Resistant CoverA clear plastic cover protects the face panel from dirt and liquids.
Estos instrumentos han sido diseñados para el control de TDS en el cultivo hidropónico, la horticultura y tratamiento de agua. De tamaño compacto, que puede ser montado en espacios confinados o incluso justo al lado de una cubeta o barril que contiene los productos químicos. Estos medidores permiten el control automático de las instalaciones previamente seleccionados de forma manual.
Las lecturas se muestran en la pantalla y el LED de varios colores de forma continua indica si el mini controlador esta en medición, administración o modo de alarma.
Los usuarios pueden elegir el modo de dosificación automático o manual con un interruptor en el panel frontal. El control manual es particularmente útil durante las operaciones de mantenimiento, ya que permite a los operadores activar o desactivar el relé de dosificación de acuerdo a su necesidad. Para ayudar a prevenir una sobredosis, el sistema de control de las horas extraordinarias aconseja a los usuarios cuando el relé está activo por mucho tiempo.
| Rango | 0.0 A 199.9 mg/L (ppm) |
|---|---|
| Resolución | 0.1 mg/L (ppm) |
| Rendimiento(@20°C/68°F) | ±2% f.s. |
| Factor de conversión TDS | 0.5 |
| Sondas | HI 7634-00 CE / TDS con sensor de temperatura interna y 2 m(6,6') de cable (no incluido) |
| Compensación de temperatura | automático, de 5 a 50º C(41 a 122º F) con b= 2% /*C |
| calibración | manual, con selector CAL |
| La dosificación de relé | máximo 2A (protegido por fusible), 250 Vac, contado, cerca de 30 VCC cuando la medida: Punto partida |
| Punto de partida | Ajustable dese 0 a 199.9 mg/L (ppm) |
| Tiempo extra | ajustables, típicamente de 5 a 30 minutos aproximadamente |
| Fuente de energia | modelos “-0”: 12 V CC del adaptador (incluido) los modelos de “-1”: 115/230 VAC ± 10% 50/60Hz; |
| Dimensiones | 79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’) |
| Peso | modelos “-0”: 200 g (7,1 oz) / modelos “-1”: 300 g (10,6 oz.) |
SONDAS
- HI 76-00 CE / TDS con la interna sensor de temperatura y 2 m (6,6 ‘) de cable
- HI 76-00 CE / TDS con sensor de temperatura interna y 4 m (13,1 ‘) de cable
- HI 76-00 CE / TDS con sensor de temperatura interna y 5 m(16,4 ‘) de cable
- HI 76 Sonda de TDS para HI 983319, de 2 m (6,6 ‘) de cable, 10 BAR
SOLUCIONES
- HI 7033L 84 mS/cm (42ppm) de solución de calibración, 500
- HI 7032L m13l82 mg/l (ppm) de solución de calibración, 500 ml
- HI 70442L 1500 mg/l (ppm) de solución de calibración,500 ml
- HI 7061L Electrodo solución de limpieza, 500 ml
ACCESORIOS
- HI 710005 115 VAC/12 VDC Adaptador de corriente
- HI 710006 230 VAC/12 VDC Adaptador de corriente
- HI 740146 Soportes de montaje
- BL 983315-0 (12 VCC), BL 983315-1 (115/230V) se suministran con soportes de montaje, la cubierta transparente y manual de instrucciones.









DQO

Valoraciones
Borrar filtrosNo hay valoraciones aún.